The oxygen booster pump is driven by compressed air, safe and explosion-proof, with two-stage pressurization.
No oil lubrication, specially used for oxygen pressurization;
Using clean stainless steel connecting pipe valve, the maximum pressure can reach 5000PSI;
Stainless steel filter is installed;
Pressure requirements:
Minimum intake pressure: 150-850psi
Maximum outlet pressure: 800-5000psi
Safety valve pressure: 800-5000psi
The noise is less than 80 dB (the measurement distance is 0.8 m according to different working conditions).
EXAMPLES OF PERFORMANCE WITH AIR DRIVE POWER OF 50 SCFM(C) AIR FLOW @AIR DRIVEN PRESSURE INDICATED | ||||
OXYGEN GAS PRESSURE-psi | OXYGEN OUTLET GAS FLOW-SCFM | |||
INLET | OUTLET | Air Driven -psi | ||
60 | 80 | 100 | ||
250 | 1500 | 3.5 | 4.0 | 4.0 |
250 | 2000 | 2.1 | 3.5 | 3.5 |
250 | 3000 | A | A | 2.5 |
1000 | 1500 | 8.7 | 14.7 | 15.0 |
1000 | 2500 | B | 9.7 | 13.7 |
1000 | 3500 | B | 9.6 | 13.6 |
1500 | 2000 | 3.5 | 4.0 | 4.0 |
1500 | 2500 | B | B | 16.1 |
1500 | 3000 | B | B | B |
2000 | 2500 | B | B | 21.6 |
A - Outlet pressure (maximum outlet pressure =30× driving gas pressure +2× inlet gas pressure);
B - Interstage stop (if the outlet pressure exceeds 30× drive gas pressure, the maximum intake pressure is 15× drive gas pressure; Otherwise, the maximum intake pressure is 15× driving gas pressure;
C - If the drive gas flow is insufficient, the outlet flow will decrease accordingly.