Air Driven Oxygen Booster

The oxygen booster pump is driven by compressed air, safe and explosion-proof, with two-stage pressurization.


No oil lubrication, specially used for oxygen pressurization;


Using clean stainless steel connecting pipe valve, the maximum pressure can reach 5000PSI;


Stainless steel filter is installed;


Pressure requirements:

Minimum intake pressure: 150-850psi

Maximum outlet pressure: 800-5000psi

Safety valve pressure: 800-5000psi


The noise is less than 80 dB (the measurement distance is 0.8 m according to different working conditions).


20200731102341.jpg


EXAMPLES OF PERFORMANCE WITH AIR DRIVE POWER OF 50 SCFM(C) AIR FLOW @AIR DRIVEN PRESSURE INDICATED
OXYGEN GAS PRESSURE-psiOXYGEN OUTLET GAS FLOW-SCFM
INLETOUTLETAir Driven -psi
6080100
25015003.54.04.0
25020002.13.53.5
2503000AA2.5
100015008.714.715.0
10002500B9.713.7
10003500B9.613.6
150020003.54.04.0
15002500BB16.1
15003000BBB
20002500BB21.6


A - Outlet pressure (maximum outlet pressure =30× driving gas pressure +2× inlet gas pressure);

B - Interstage stop (if the outlet pressure exceeds 30× drive gas pressure, the maximum intake pressure is 15× drive gas pressure; Otherwise, the maximum intake pressure is 15× driving gas pressure;

C - If the drive gas flow is insufficient, the outlet flow will decrease accordingly.