Introduction to high vacuum equipment:
The high vacuum acquisition device is a vacuum system composed of kf-50 stainless steel metal oil diffusion pump, 2xz-4 rotary vane vacuum pump, high vacuum solenoid valve, high vacuum valve and stainless steel bellows. It can reduce the limit vacuum degree of mechanical vacuum pump (5pa-6x10-2pa), By adding stainless steel metal diffusion pump, the limit vacuum degree of the system can reach the range of 1 × 10 - 2 power to 1 × 10 - 4 power PA. The vacuum acquisition device is small in size, light in weight, and can be moved freely. The cooling system of diffusion pump is air-cooled, clean, environmentally friendly, efficient and pollution-free. It can be built according to the needs of customers, with box structure or frame structure. The requirements of vacuum chamber can also be designed and manufactured according to the requirements of customers, but some users do not need the vacuum chamber, as long as a suction is left It's just a matter of words.
Simple operation instructions for high vacuum equipment:
1. First, connect all the matching parts according to the design requirements, connect the power supply, turn on the vacuum gauge measurement, and then start the mechanical vacuum pump to pre pump the vacuum system, so that the vacuum degree of the whole system is pumped below 5pa from atmospheric pressure, and then turn on the heating power supply of the diffusion pump and the fan power supply for cooling the diffusion pump body. In the first ten minutes of the diffusion pump heating, the vacuum will have a process of amplification and decline, but with the evaporation of oil vapor in the diffusion pump, the vacuum degree will gradually reduce and rise again, and the ideal vacuum degree can be reached about 20 ~ 40 minutes.
2. After the test work is completed, first cut off the heating power supply of diffusion pump, and then turn off the cooling fan, then turn off the power supply of vacuum gauge, and finally turn off the power supply of vacuum pump; remember: it is strictly forbidden to put gas into the vacuum system in the high vacuum measurement state, so as not to directly damage the performance of the diffusion pump oil and never raise the limit vacuum degree.
3. Due to the different requirements put forward by various users when purchasing the equipment, the specific operation instructions will be specially prepared, which can only be written here on the website. Please understand and look forward to your sincere inquiry.