Vacuum Drying Plant Structure :
1, Vacuum drying chamber
2, Vacuum system
3, Closed hot air circulation system
4, Thermal oil heating system
5, Refrigeration system
6, Compressed air system
7, Cooling water system
8, Hydraulic system and two chambers open cover mechanism
9, Measurement and control system
Vacuum Drying Plant Technical Paramters :
Name | Hot air circulation vacuum drying curing oven | Technical Parameters (Can be adjusted according to user requirements) |
Technical Parameters | ||
Power | 3 Phase 380V 50HZ | |
Operating temperature range | From room temperature to 200 ℃ | |
Empty furnace heating time | 40~100℃/h | |
Furnace surface temperature rise | ≤Room temperature+25℃ | |
Temperature fluctuation | ≤±1℃ | |
Temperature uniformity | ≤±25%(referring to the highest temperature) | |
The heating power | Based on the oven volume | |
Blasting power | 0.75KW/ unit, the number to be determined | |
Exhaust power | 0.75KW/1unit | |
Effective size | ||
1600*1800*2000mm(W*H*L) | ||
2000*2000*3000mm(W*H*L) | ||
2000*2000*3500mm(W*H*L) | ||
Can be customized according to user requirements of non-standard size | ||
Trolley size | The box of this package | |
Furnace body | The overall framework of the structure, large oven site with do | |
Door | Manually open the front of the furnace door | |
Shell | Q235 cold-rolled steel plate after anti-rust treatment, spraying acrylic dry paint | |
Liner | Q235 cold-rolled steel plate by rust treatment, spraying W61 series of silicone heat-resistant paint | |
Shell skeleton | Q235 channel, angle steel rust treatment | |
Liner skeleton | Q235 rust-proof steel angle rust treatment, spraying W62 silicone temperature system paint | |
Insulation Materials | High-quality aluminum silicate cotton, rock wool or other insulation materials |
Rectangular chamber :
Dimension (mm) | Ultimate Vacuum | Leakage Rate | Operating Temp. | Temp. Accuracy | Control Mode |
4000×2500×2500 | ≤50Pa (unload) | ≤500Pa.L/S | 115±5℃ | ±5℃ | Auto control by HMI |
4000×3000×3000 |
≤50Pa (unload) | ≤500Pa.L/S | 115±5℃ | ±5℃ | Auto control by HMI |
5000×3000×3000 | ≤10Pa ≤10Pa (unload) | ≤500Pa.L/S | 115±5℃ | ±5℃ |
Auto control by HMI |
5000×3000×3500 | ≤10Pa ≤10Pa (unload) | ≤500Pa.L/S | 115±5℃ | ±5℃ | Auto control by HMI |