1. Before assembly, it is necessary to fully blow away the chips and dust in the piping to prevent the mixing of sealing material fragments.
2. Import and export direction shall not be installed in the opposite direction. To install vertically, cup downwards. In order to facilitate maintenance, appropriate space should be set aside above and below.
3. It shall not be installed near the air compressor. Because the air temperature is higher, a lot of water is still in the state of steam. It should be installed near the gas device to ensure that most of the moisture in the air has been condensed into liquid water
4, when the water level is close to the baffle to drain, or regularly discharge condensed water. Discharge by hand, not with tools. If you forget to discharge the condensed water, once the condensed water reaches the filter element, the separated condensed water will flow out from the secondary side, polluting the downstream pneumatic components, you must pay attention.
5. In order to prevent the water cup from breaking and injuring others, a metal protective cover shall be installed outside the water cup. Check the glass regularly for cracks and contamination.
6. Avoid sunlight.