PRODUCT PARAMETER:
1, the maximum long-term continuous working temperature: 2850 °C (12 hours or more)
2, the maximum design temperature: 3000 °C (maximum temperature continuous time <2 hours)
3, the furnace working atmosphere: nitrogen, argon (flow < 0.5m3 / h), vacuum (not more than 2300 degrees, please specify when ordering)
4, furnace size: φ200 × 350mm (inside the loading space)
5, rated output power: 60KW, the actual power is not more than 50KW
6, rated frequency frequency: 4000Hz
7, temperature measurement method: two-color infrared temperature measurement
8, temperature range: 1000-3200 °C, (0-3200 °C full range of temperature measurement, please specify when ordering, standard starting with 1000 °C)
9, temperature control method: automatic program temperature control
10, equipment use: high temperature graphitization
11. Cooling water usage: ≤20m7/h (this equipment is provided)
12. Reserve water usage: ≤8m7/h (self-provided by the equipment)
13. Internal circulating water quality: distilled water or pure water
14. Internal circulating water pressure: 0.2~0.3MPa
15, power supply grid: three-phase five-wire system 380V, 50Hz/60Hz
16, cooling protection: the use of flow, pressure, water temperature on the cooling water and other multiple protection.
17, the limit heating rate: less than 60 minutes.
Product model | IVG-130H | IVG-200 H | IVG-260 H | IVG-300 H | IVG-500 H |
specifications (diameter x length mm) | Φ400×1000 | Φ500×1000 | Φ600×1200 | Φ700×1600 | Φ900×1600 |
IF power supply Kw | 130 | 200 | 260 | 300 | 500 |
IF power supply frequency Hz | 1500 | 1000 | 1000 | 1000 | 1000 |
Maximum operating temperature °C | 3000 | 3000 | 3000 | 3000 | 2850 |
Ultimate vacuum Pa | 1.2×10-1 | 1.2×10-1 | 1.2×10-1 | 1.2×10-1 | 1.2×10-1 |
Pressure rise rate Pa/h | 0.67 | 0.67 | 0.67 | 0.67 | 0.67 |
Constant temperature zone temperature difference °C | ±10 | ±10 | ±10 | ±10 | ±15 |