Molybdenum disilicide (MoSi2) heating element is a resistance generate-heating component made from MoSi2 or the basic material. It is used in high temperature under the oxidizing atmosphere, it looks like glass in its surface and form a light SiO2 glass film which can protect the element not to be oxidized. So this kind of element has unique effect for resisting oxidization in the high temperature. It is used to the highest temperature up to 1800C during oxidizing atmosphere. According to your request, our company can produce the products of Pole, "U", "W" and "U"-right angle shapes, etc.

 

Application

· Laboratory furnace

· Industrial furnace

· Sintering furnace

· Glass melting furnace

· Testing equipment 

· Heat treatment

· Metal sintering

  The Physical Properties of Molybdenum Disilicide Heating Element

Operation of Furnace

1. Drying of Furnace

The new built furnace or the furnace that haven't been used for a long time should be dried before use.The drying temperature

generally is 100°C-200°C. The element used for a long time under low temperature will cause oxidation. For the small size

furnace, as its drying time is short, several hours will have small impact on the element. For large size furnace, as the drying

time is long, it had better use other heating elements to dry furnace. Had better open the furnace gate to make it ventilated.

The gate may be half open with the rising of temperature and fully closed when the temperature rises above 1000°C.

 

2. Notice to Furnace Operation

To avoid high current surges which may cause damage to MoSi2 Heating Elements, the recommend starting procedure

as following:

 

Small Furnace (Power <100KW)

Big Furnace (Power 100KW-500KW)

Furnace Temperature .C

Voltage

Furnace Temperature .C

Voltage

20-150

1/3 Working Voltage

20-300

1/3 Working Voltage

150-500

2/3 Working Voltage

300-700

1/3 Working Voltage

500-Working Temperature

Full Working Voltage

700-working Temperature

Full Working Voltage

 

Replacement of Element

If it is found that one element is damaged during operation, you should determine where it is and prepare one made

up element simultanously. Then loose the screw which links the lead wire of the damaged element and the bus, clear

out the ceramic cotton and pull out the throughbrick. Afterward, insert the new element from the furnace top, link the lead

wire, block the gap with ceramic cotton and start rising temperature.

 